微机灰熔点测定仪摄像头的调试步骤

装置好摄像头后,,,摄像头距离灰熔点炉体的间距为150mm

After installing the camera, the distance between the camera and the ash melting point furnace body is 150mm

 

 

 

 

 

 

 

摄像头介绍

Camera Introduction

微机灰熔点测定仪摄像头的调试步骤

摄像头三个旋钮调整,,,早年到后作用别离是::

The three knobs of the camera are adjusted, and their effects from front to back are:

调整画面巨细

Adjusting the screen size

调整画面明暗

Adjusting the brightness of the screen

调整画面清澈度

Adjusting the clarity of the screen

 

画面调整

Screen adjustment

微机灰熔点测定仪摄像头的调试步骤

设备起头后,,,温度达到900时弹出提醒。。不重点击对话框中的知晓了,,,这时起头调整摄像头。。把稳::调整速度要快,,,设备到1000后系统会自动起头尝试,,,导致调整失效

After the device starts, a prompt will pop up when the temperature reaches 900 . Don't click on "Got it" in the dialog box, then start adjusting the camera. Attention: The adjustment speed should be fast. After the device reaches 1000 , the system will automatically start the experiment, causing the adjustment to fail

 

 

微机灰熔点测定仪摄像头的调试步骤

先调整画面焦距,,,就是摄像头zui内侧的旋钮,,,调整到样品边缘清澈即可。。如下图

First adjust the focal length of the image, which is the innermost knob of the camera, until the sample edge is clear. As shown in the following figure

微机灰熔点测定仪摄像头的调试步骤微机灰熔点测定仪摄像头的调试步骤

而后用摄像头中央那个旋钮来调整画面的亮度,,,不能太亮也不能太暗。。如下图

Then use the knob in the middle of the camera to adjust the brightness of the image, which should not be too bright or too dark. As shown in the following figure

微机灰熔点测定仪摄像头的调试步骤微机灰熔点测定仪摄像头的调试步骤

最后调整画面巨细,,,用摄像头zui外侧的,,,先将带编号的方框齐全框住样品,,,尖头部门不必要齐全顶住编号方框的顶部。。

Finally, adjust the picture size. Use the outermost part of the camera to completely frame the sample with the numbered box. The pointed part does not need to completely support the top of the "numbered box".

微机灰熔点测定仪摄像头的调试步骤

 

微机灰熔点测定仪摄像头的调试步骤

 

画面调整好之后点击弹出对话框中的知晓了

After adjusting the screen, click "Got it" in the pop-up dialog box

 

微机灰熔点测定仪摄像头的调试步骤

而后用鼠标点击界面中的原型画面。。

Then click on the "prototype" screen in the interface with the mouse.

 


点击过原型画面后,,,系统会固定目前的亮度,,,而后就算灰熔点测定仪摄像头调试结束

After clicking on the "prototype" screen, the system will fix the current brightness, and then even after debugging is completed

 

具体详情可联系鹤壁GCGC黄金城官网公司进行征询0392-3388939 3388929

GCGC黄金城官网专业从事煤质化验设备,,,煤质化验仪器,,,煤炭检测设备,,,煤炭化验仪器,,,煤炭化验设备,,,煤焦化验仪器煤焦化验设备的开发、、 、研制、、 、出产、、 、销售、、 、和服务。。详情请征询::15303929722。。

CopyRight ? 版权所有: GCGC黄金城官网. 技术支持:鹤壁新起点 网站地图 XML 登记号:豫ICP备16008222号-4

本站关键字: 量热仪 全自动量热仪 量热仪价值 量热仪厂家

EG8vqtpYrln2TPrxyxXt+LHTu3qUf1A8zAU63uj+vBAAAAABJRU5ErkJggg==
扫一扫接见移动端
EG8vqtpYrln2TPrxyxXt+LHTu3qUf1A8zAU63uj+vBAAAAABJRU5ErkJggg==
【网站地图】